BENSHAW RSi GX Series Hardware Manual page 120

Sensorless vector variable frequency drive
Table of Contents

Advertisement

6 - Parameter Descriptions
I17-I24: Multi-Function Input Terminals
Range:
Description:
114
Ex 1) The drive determines the freq reference is lost when DRV- Frq is set
to 3 (Analog V1 input), I 16 to 1 and analog input signal is less than half the
value set in I 7.
Ex 2) The drive determines the freq reference is lost when DRV- Frq is set
to 6 (V1+I), I 16 to 2 and V1 input signal is either below the value set in I 7
or I input value is less than the I 12 value.
0-24
The multi-function input terminals can be defined for many different
applications. The following table shows the various programmable
functions.
Code
I17
I18
I19
I20
I21
I22
I23
I24
Setting
Range
Description
Display
0
Forward Run
1
Reverse Run
2
Stop Trip
3
Reset [RST]
4
Jog Operation
5
Step freq - Low
6
Step freq - Mid
7
Step freq - High
8
Accel/Decel - Low
9
Accel/Decel - Mid
10
Accel/Decel - High
11
DC brake
12
2nd motor
Display
Default
P1 define
P2 define
P3 define
P4 define
P5 define
P6 define
P7 define
P8 define
Setting
Range
Display
13
14
15
16
17
18
19
20
21
22
23
24
Setting
0
1
2
3
See table below
4
5
6
7
Description
-Reserved-
-Reserved-
Frequency (Up) Command
Frequency (Down)
Command
3-wire operation
External trip: A (EtA)
External trip: B (EtB)
Self-diagnostic
Exchange between PID
operation and V/F operation
Exchange between Option
and drive
Analog Hold
Accel/Decel Disable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents