BENSHAW RSi GX Series Hardware Manual page 119

Sensorless vector variable frequency drive
Table of Contents

Advertisement

Range:
Description:
Range:
Description:
These parameters are used to adjust the scaling the -10 to 0V analog input
signal. The scaling and slope of the analog signal is adjusted by setting
parameters I2-I5. A filter time can also be set to reduce the affects of noise
on the analog signal. This parameter is active if Frq is set to 3 or 5.
Code
Default
I12
4mA
I13
0Hz
Set freq.
I10
I8
I11 is the filtering time constant for the V1 (0-10Vdc) input. Increasing this
value will reduce the drive's response to noise. However, increasing this
parameter will also make the drive respond slower to speed changes.
0 - 2 (Default: 0)
This is to set the criteria for loss of analog input signal when DRV-15
[Frequency Mode] is set to 'V1', 'V1S' 'I', 'V1+I' or 'Pulse'. This function
is does not operate when the set to V1 +I.
Display:
Function:
0
Disabled.
1
Activated below half of set value.
2
Activated below set value.
6 - Parameter Descriptions
I11 - I15: Bias and Gain of the -10 to 0V Signal
Setting
Code
0-20mA
I14
0~Max.
I15
freq
50Hz
10Hz
2V
8V
I9
I7
I16: Criteria for Analog Input Signal Loss
Default
Setting
20mA
0~20mA
0~Max.
60Hz
freq
V0 input
113