BENSHAW RSi GX Series Hardware Manual page 118

Sensorless vector variable frequency drive
Table of Contents

Advertisement

6 - Parameter Descriptions
I6 - I10: Bias and Gain of the -10 to 0V Signal
Range:
Description:
112
These parameters are used to adjust the scaling of the V1 (-10 to 0V) analog
input signal. The scaling and slope of the analog signal is adjusted by setting
parameters I2-I5. A filter time can also be set to reduce the affects of noise
on the analog signal. This parameter is active if Frq is set to 3 or 5.
Code
Default
I7
0V
I8
0Hz
Set freq.
I10
10Hz
I8
I6 is the filtering time constant for the V1 (0-10Vdc) input. Increasing this
value will reduce the drive's response to noise. However, increasing this
parameter will also make the drive respond slower to speed changes.
Setting
Code
Default
0-10V
I9
10V
0~Max.
I10
60Hz
freq
50Hz
2V
8V
I9
I7
Setting
0~10V
0~Max.
freq
V0 input