These functions are displayed only when one of the multifunction inputs is set at '2nd func'
in I7 to I24.
The purpose of these parameters is to provide the user with a second set of motor
parameters selected with a digital input. This can be useful on test stands, where a user will
be testing different types of applications.
In the table below, the 1st functions are applied if the multifunction terminal is not defined
to '2nd Func' or if it is not ON. The 2nd function parameters are applied when the
multifunction input terminal is set to '2nd Func' and is ON. Parameters not listed on the
table below are applied to the 2nd motor as well as the 1st motor.
The 'User V/F' function of F29 [V/F Pattern] is used for both the 1st motor and the 2nd
motor.
Description
Acceleration Time
Deceleration Time
Base Frequency
Volts/Hz Pattern
Forward Torque Boost
Reverse Torque Boost
Stall Prevention Level
ETH Level for 1 Minute
ETH Level for Continuous
Motor Rated Current
z Note: The exchanging of motors must be performed when the motors are stopped.
An Overvoltage or overcurrent fault can occur when the motor connection is exchanged
during operation.
H81 - H90: 2nd Motor Related Functions
1st Functions
ACC [Accel time]
dEC [Decel time]
F22 [Base Freq.]
F30 [V/F pattern]
F28 [FWD Boost]
F29 [Rev Boost]
F59 [Stall prevention level]
F51 [ETH 1 min.]
F52 [ETH continuous]
6 - Parameter Descriptions
2nd Functions
H81 [2nd Acc time]
H82 [2nd Dec time]
H83 [2nd Base Freq.]
H84 [2nd V/F pattern]
H85 [2nd Fwd Boost]
H86 [2nd Rev Boost]
H87 [2nd Stall prevention level]
H88 [2nd ETH 1 min.]
H89 [2nd ETH continuous]
H90 [2nd Motor rated current]