6 - Parameter Descriptions
H70: Max. Freq
Output freq
Accel time
H71: Accel/Decel Time Scale
Range:
Description:
H72: Power on Display
Range:
Description:
102
Max freq
Decel time
0-2 (Default: 1)
This is used to change the resolution for the acceleration and deceleration
times.
Setting Range
Display
Select
0.01 sec. The Accel/Decel time is changed by 0.01 sec./10msec.
0
1
0.1 sec.
2
1 sec.
0 - 13 (Default: 0)
This parameter selects the first parameter to be displayed on the keypad
when the input power is first applied.
Display
Description
0
Frequency command (0.00)
1
Accel time (ACC)
2
Decel time (DEC)
3
Drive mode (drv)
4
Frequency mode (Frq)
5
Multi-Step frequency 1
6
Multi-Step frequency 2
H70: Delta Freq
Certain freq
Accel time
Description
The maximum setting range is 60 seconds.
The Aceel/Decel time is changed by 0.1 sec./100 msec.
The maximum setting range is 600 seconds.
The Accel/Decel time is changed by 1 second. The
maximum setting range is 6000 seconds.
Display
7
8
9
10
11
12
13
Next target freq
Decel time
Description
Multi-Step frequency 3
Output current (CUr)
Motor rpm (rPM)
Inverter DC link voltage
(dCL)
User display select (vOL)
Fault display 1
Operating direction select