Figure 114. Installing a power supply unit blank
Next step
Follow the procedure listed in

Removing a power supply unit

The procedure for removing AC and DC PSUs is identical.
Prerequisites
CAUTION:
The system needs one power supply unit (PSU) for normal operation. On power-redundant systems, remove and
replace only one PSU at a time in a system that is powered on.
1
Follow the safety guidelines listed in
2
Disconnect the power cable from the power source and from the PSU you intend to remove, and then remove the cable from the
strap on the PSU handle.
3
Unlatch and lift the optional cable management arm if it interferes with the PSU removal.
For information about the cable management arm, see the system's rack documentation at Dell.com/poweredgemanuals.
Step
Press the release latch and slide the PSU out of the system by using the PSU handle.
After working inside your
system.
Safety
instructions.
Installing and removing system components