Standard operating temperature

Table 31. Standard operating temperature specifications
Standard operating temperature
Continuous operation (for altitude less than 950 m or 3117
ft)

Expanded operating temperature

Table 32. Expanded operating temperature specifications
Expanded operating temperature
Continuous operation
≤ 1% of annual operating hours
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings may be reported on the bezel's LCD
panel and in the System Event Log.
Expanded operating temperature restrictions
Do not perform a cold startup below 5°C.
The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
Redundant power supply configuration is required.
AEP DIMM is not supported.
GPGPU card is not supported.
Rear drive configuration is not supported.
12 x 3.5 inch SM configuration with CPU 140 W/130 W/115 W/105 W_4C is not supported.
LRDIMM is not supported.
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
Tape backup unit (TBU) is not supported.
Specifications
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Specifications
5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to
40°C), the system can operate continuously in temperatures as low
as 5°C and as high as 40°C.
For temperatures between 35°C and 40°C, de-rate maximum allowable
temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
–5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to
40°C), the system can operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable
temperature by 1°C per 125 m above 950 m (1°F per 228 ft).