Removing The Non-Fabric Processor From The Processor And Heat Sink Module - Dell EMC PowerEdge R540 Installation And Service Manual

Table of Contents

Advertisement

3
Remove the air shroud.
Steps
1
Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order below:
a
Loosen the first screw three turns.
b Loosen the second screw completely.
c
Return to the first screw and loosen it completely.
2
Pushing both blue retention clips simultaneously, lift the processor and heat sink module (PHM) processor and heat sink module
3
Set the PHM aside with the processor side facing up.
Figure 58. Removing processor and heat sink module
Next step
Installing a processor and heat sink module
Removing the non-fabric processor from the processor and
heat sink module
Prerequisites
NOTE:
Only remove the processor from the processor and heat sink module if you are replacing the processor or heat sink. This
procedure is not required when replacing a system board.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
3
Removing the air shroud
4
Removing a processor and heat sink module
Safety
instructions.
Before working inside your
system.
Installing and removing system components
107