If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to the sleep
state.
You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User's Guide available at
https://www.dell.com/support/home/us/en/19/product-support/product/poweredge-r6515/overview.

Remove the power supply unit blank

Prerequisites
Follow the safety guidelines listed in the
Steps
Pull the blank out of the system.
CAUTION:
To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a non-redundant
configuration. Remove the PSU blank only if you are installing a second PSU.
Figure 85. Removing a power supply unit blank
Next steps
Replace the
PSU
or
PSU
blank.

Install the power supply unit blank

Prerequisites
Follow the safety guidelines listed in the
NOTE:
Install the power supply unit (PSU) blank only in the second PSU bay.
Remove a power supply
Steps
Align the PSU blank with the PSU bay and push it into the PSU bay until it clicks into place.