Power Interposer Board; Removing Power Interposer Board - Dell EMC PowerEdge R540 Installation And Service Manual

Table of Contents

Advertisement

WARNING:
Reversing polarity when connecting DC power wires can permanently damage the power supply or the system.
2
Insert the copper ends into the mating connectors and tighten the captive screws at the top of the mating connector using a Phillips
#2 screwdriver.
WARNING:
To protect the power supply from electrostatic discharge, the captive screws must be covered with the rubber
cap before inserting the mating connector into the power supply.
3
Rotate the rubber cap clockwise to fix it over the captive screws.
4
Insert the mating connector into the power supply.

Power interposer board

Removing power interposer board

Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
3
Removing the air shroud
4
Disconnect all the cables connected from the PIB to the system board.
NOTE:
Ensure that you note the routing of the cables as you remove them from the system board.
5
Removing a processor and heat sink module
Steps
1
Using a Phillips #2 screwdriver, remove the screw securing the power interposer board (PIB) to the system.
2
Press the blue release latch on the PIB to release it from the hook on the PSU cage.
3
Lift the board and slide it out at an angle to disengage the guide pins on the board.