Administration
System Log
STEP 1
STEP 2
STEP 3
STEP 4
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4
To define SYSLOG servers:
Click Administration > System Log > Remote Log Servers.
Enter the following fields:
IPv4 Source Interface—Select the source interface whose IPv4 address will be used as
the source IPv4 address of SYSLOG messages sent to SYSLOG servers.
IPv6 Source Interface—Select the source interface whose IPv6 address will be used as
the source IPv6 address of SYSLOG messages sent to SYSLOG servers.
If the Auto option is selected, the system takes the source IP address from the IP
NOTE
address defined on the outgoing interface.
Information is described for each previously-configured log server. The fields are described
below in the Add page.
Click Add.
Enter the parameters.
Server Definition—Select whether to identify the remote log server by IP address or
name.
IP Version—Select the supported IP format.
IPv6 Address Type—Select the IPv6 address type (if IPv6 is used). The options are:
-
Link Local—The IPv6 address uniquely identifies hosts on a single network link. A
link local address has a prefix of FE80::/10, is not routable, and can be used for
communication only on the local network. Only one link local address is supported.
If a link local address exists on the interface, this entry replaces the address in the
configuration.
-
Global—The IPv6 address is a global Unicast IPV6 type that is visible and
reachable from other networks.
Link Local Interface—Select the link local interface (if IPv6 Address Type Link Local
is selected) from the list.
Log Server IP Address/Name—Enter the IP address or domain name of the log server.
UDP Port—Enter the UDP port to which the log messages are sent.
Facility—Select a facility value from which system logs are sent to the remote server.
Only one facility value can be assigned to a server. If a second facility code is assigned,
the first facility value is overridden.