1. Cooling system air bleed hose
2. Clamp
3. Radiator outlet hose
4. Hose clamp
5. Water pump inlet pipe
6. Water pump outlet pipe
7. Thermostat assembly
A. Install the clamp with the end pointing
upward. Make sure that the clamp is not
installed on the flange of the hose fitting of
the radiator hose.
B. Align the white paint mark on the radiator out-
let hose, projection on the radiator, and open-
ing of the hose clamp.
Install the radiator outlet hose up to the cen-
ter of the projection on the radiator.
After installing the hose clamp, the end of the
radiator outlet hose should be over the pro-
jection on the radiator.
C. Align the yellow paint mark on the radiator
outlet hose with the white paint mark on the
water pump inlet pipe and the opening of the
hose clamp. Insert the radiator outlet hose up
to the center of the white paint mark on the
water pump inlet pipe.
D. Clamp installation details
E. 2 mm (0.08 in) or more
F. Installed length: 20 mm (0.79 in)
G. Make sure that the clamp is not installed on
the flange of the hose fitting.
H. Yellow paint mark on the radiator outlet hose
I. Hose clamp opening
J. 45
K. Point the projections (2 locations) on the
hose clamp downward.
L. Hose clamp installation details
M. 3 mm (0.12 in) or more
N. Plug-in length
O. Make sure that the hose clamp is not
installed on the flange of the hose fitting of
the water pump inlet pipe.
P. Make sure that the hose clamp is not
installed in a slanted position as shown in the
illustration.
Q. Make sure to hook the end of the hose clamp
securely onto the projection on the hose
clamp. (not like as shown illustration)
R. Install the hose clamp so that both ends are
parallel to each other.
S. Make sure that the projection on the center of
the hose clamp contacts with the cut out in
the end of the hose clamp.
2-82