Procleix TIGRIS Operator's Manual page 145

Table of Contents

Advertisement

Magnetic Wash Stations. Separate the target
RNA/DNA from plasma and other potential
inhibitors during the target capture process.
p. 1-19
M a s t e r L o t . G r o u p i n g f o r s e ts o f A R s .
Individual ARs belong to a set; sets of ARs
belong to a Master Lot. All ARs in a set must
belong to the same Master Lot to be used
together. p. 2-20
Master Lot Report. Contains the individual lots
of Assay Reagents that make up a Master Lot.
p. 6-7
Matched Kit. See Matched Set.
Matched Set. A set of ARs that are tracked
and always used together on the system. The
first time that a new set of ARs is loaded, the
system records the barcode information for the
individual bottles. From that point on, these
individual bottles must be run as a set. p. 2-22
MTU. See Multi-Tube Unit.
MTU Drawer. Drawer for loading and storing
up to 20 MTUs. pp. 1-9, 2-7
MTU Tiplets. Single-use disposable tips stored
on the MTU connectors that are used to
aspirate Wash Solution from the MTU and to
perform liquid level sensing. p. 1-19
MTU Waste Container. Waste container for
used Multi-Tube Units and Pipette Tips, located
at the rear of the Waste Drawer. pp. 1-11, 2-17
MTU Waste Cover. A cover for the MTU
Waste Container to prevent splashing or
spilling of waste. pp. 1-11, 2-17
MTU Waste Deflector. Guides MTUs and
pipette tips into the MTU Waste Container to
prevent waste accumulation in one area.
pp. 1-11, 2-17
Multi-Tube Unit. Group of five disposable
polypropylene reaction tubes. All PROCLEIX
TIGRIS System reactions take place in an
MTU. p. 2-7
NTP. Nucleotide Triphosphate. p. 1-19
®
PROCLEIX
TIGRIS System Operator's Manual
Volume I: Operating the Instrument
N
Oil. Dispensed into the MTU at the start of
TMA to prevent sample evaporation and
environmental contamination. pp. 1-19, 2-12
Operator Rights Report. Contains all of the
properties and rights for all operator accounts
in the PROCLEIX TIGRIS System database.
p. 6-8
Pipette Tips. Disposable single use tips used
to aspirate and dispense sample and TCR into
an MTU, and to perform liquid level sensing.
p. 1-14
Pipette Tip Ring. Holds up to five trays of
disposable pipette tips. p. 1-14
P r o b e R e a g e n t . C o n t a i n s A E - l a b e l e d
oligonucleotides; dispensed during HPA to
hybridize to the amplicon. pp. 1-13, 1-20
PROCLEIX TIGRIS Control. Controls that are
run with each worklist to validate assay results.
Refer to the appropriate PROCLEIX
Control package insert for contents and use.
p. 3-2
Quadrant. Describes one cluster section of the
AR or TCR Carousel, which holds one set of
Assay Reagents. pp. 1-12, 2-24
Relative Light Units. The luminometer output
o f t h e l i g h t s i g n a l r e a d d u r i n g t h e
chemiluminescent reaction. pp. 1-20, 4-2
Results Report. Contains comprehensive
Assay Reagent and sample result information
for the specified worklist. p. 6-9
Return Times. Panel at the right side of the
Status Panel that contains estimated times for
when the operator can load MTUs, pipette tips,
sample racks, obtain worklist results, and be
automatically logged off by the system. p. 2-3
RLU. See Relative Light Units.
I
NDEX
O
P
®
TIGRIS
Q
R
Part # 902649EN Rev. A
i-3

Advertisement

Table of Contents
loading