2.3.22 SAFEMODESTATUS

Safe Mode Status
Platform: OEM729, OEM719, OEM7700
This log provides additional information about the state of the receiver in the event that the Safe
Mode error bit and/or Reset Loop Detected status bit are set in the RXSTATUS log (see page
134).
The data within this log is set at receiver start up and will not change over time.
Message ID: 2060
Log Type: Asynch
Recommended Input:
log SAFEMODESTATUSA once
Abbreviated ASCII Example:
#SAFEMODESTATUSA,COM1,0,89.0,UNKNOWN,0,0.000,024c0020,8e55,32768;SAFE_
MODE_OK,0,"Normal Operation."*29c7d28a
Field
Field Type
SAFEMODESTATUS
1
header
2
Status
3
Reset Count
4
Description
5
xxxx
6
[CR][LF]
OEM6 to OEM7 Integration Guide v1
Description
Log header. See Messages for more
information.
Safe Mode State. See Table 59: Safe
Mode States on the next page
Number of resets since power up or a
successful boot
String for additional information about
the Safe Mode State
32-bit CRC (ASCII and Binary only)
Sentence terminator (ASCII only)
Binary
Binary
Binary
Format
Bytes
Offset
-
H
0
Enum
4
H
Ulong
4
H+4
String
80
H+8
Ulong
4
H+88
-
-
-