2.2.26 REFERENCESTATIONTIMEOUT

Sets timeout for removing previously stored base stations
Platform: OEM729, OEM719, OEM7700
This command sets how long the receiver will retain RTK base station co-ordinates. Shorter dur-
ations might be required if the receiver is operating in a VRS RTK network that recycles base sta-
tion IDs quickly.
Message ID: 2033
Abbreviated ASCII Syntax:
REFERENCESTATIONTIMEOUT option [timeout]
Factory Default:
REFERENCESTATIONTIMEOUT AUTO
ASCII Example:
REFERENCESTATIONTIMEOUT SET 90
Field
Field Type
REFERENCESTATION
1
TIMEOUT header
2
option
3
timeout
1
This behavior is subject to change.
OEM6 to OEM7 Integration Guide v1
ASCII
Binary
Value
Value
Command header.
-
-
See Messages for
more information.
Sets the Timeout to
90 seconds
AUTO
1
The Timeout field is
optional for AUTO
and has no effect
Must set the
timeout value using
the Timeout field
SET
2
0 is not accepted
when using the SET
option
1 to 3600 s
Specify the time
Description
Format
-
1
Enum
Ulong
Binary
Binary
Bytes
Offset
H
0
4
H
4
H+4
61