J1939Config - Novatel OEM6 Integration Manual

Hide thumbs Also See for OEM6:
Table of Contents

Advertisement

Chapter 2   New for OEM7 – Firmware

2.2.19 J1939CONFIG

Configure CAN network-level parameters
Platform: OEM729, OEM719, OEM7700
Use this command to configure the CAN J1939 network-level parameters (NAME, etc).
Issuing this command may initiate a CAN 'Address Claim' procedure. The status of the node and
address claim are reported in the J1939STATUS log (see page 112).
Once a "node" is configured using J1939CONFIG, and the "port" is configured to ON using
CANCONFIG "port" ON, J1939CONFIG "node" cannot be entered again until the "port" is con-
figured to "OFF" using CANCONFIG "port" OFF. (See the CANCONFIG command on page 16
Message ID: 1903
Abbreviated ASCII Syntax:
J1939CONFIG node port [pref_addr [alt_addr_range_start] [alt_addr_range_end]
[mfgcode] [industry] [devclass] [devinstance] [func] [funcinstance]
[ECUinstance]]
Factory Default:
J1939CONFIG NODE1 CAN1 1C 0 FD 305 2 0 0 23 0 0
J1939CONFIG NODE2 CAN2 1C 0 FD 305 2 0 0 23 0 0
ASCII Example :
J1939CONFIG NODE1 CAN1 AA 0 FD 305 2 0 0 23 0 0
Field
Field Type
J1939CONFIG
1
header
2
node
3
port
4
pref_addr
OEM6 to OEM7 Integration Guide v1
ASCII
Binary
Value
Value
Command header. See
-
-
Messages for more
information.
NODE1
1
Identifies the J1939 Node
(i.e. CAN NAME)
NODE2
2
CAN1
1
Physical CAN port to use
CAN2
2
Preferred CAN address.
The receiver attempts to
0x0 - 0xFD
claim this address
(default = 0x0)
Description
Binary
Binary
Format
Bytes
Offset
-
H
0
Enum
4
H
Enum
4
H+4
Ulong
4
H+8
50