2. Commissioning
Module
Module
no.
0
Fieldbus node CPX-FB32 with
status bits
1
Digital 8-input module CPX-8DE
2
Digital 8-input module CPX-8DE
3
Digital 4-output module
CPX-4DA
4
Digital multi I/O module
CPX-8DE-8DA
5
Analogue 2-output module
CPX-2AA
6
VTSA pneumatic interface set with
DIL switch to 1 ... 8 valve coils
1)
16 bits occupied, 8 bits used
2)
8 bits occupied, 4 bits used
Tab. 2/10: Addressing the example terminal 3 (see Fig. 2/3)
2-16
Input address
1)
I0 ... I15
I16 ... I23
I24 ... I31
I32 ... I39
Festo P.BE-CPX-FB32-EN en 1111a
Output address
2)
O32 ... O39
O40 ... O47
O0 ... O31
O48 ... O55