1. Installation
1.4

Pin assignment of power supply

Festo P.BE-CPX-FB32-EN en 1111a
Warning
• Use for the electrical power supply only PELV circuits in
accordance with EN 60204-1
(Protective Extra-Low Voltage, PELV).
• Also consider the general requirements for PELV circuits
in accordance with EN 60204-1.
• Use only voltage sources that ensure a reliable electric
separation of operating voltage in accordance with
EN 60204-1.
Through the use of PELV circuits, protection from electric
shock (protection from direct and indirect contact) in
accordance with EN 60204-1 is ensured (Electrical equipment
of machines. General requirements).
The current consumption of a CPX terminal depends on the
number and type of integrated modules and components.
Read the information on power supply as well as on the
earthing measures to be carried out in the CPX system
manual.