2. Commissioning

2.1

Addressing

Festo P.BE-CPX-FB32-EN en 1111a
Before configuring, ascertain the exact number of available
inputs/outputs. A CPX terminal consists of a different number
of I/Os, depending on what you have ordered and on the
configuration of the field bus node. The I/Os will be assigned
automatically within the CPX terminal.
Note
– Maximum 10 electric modules including the fieldbus
node plus a pneumatic interface or MPA pneumatic
modules are permitted on a CPX terminal.
– If you configure the CPX terminal with an EDS file,
the field bus node in the first location must be installed
as module 0.
– The CPX terminal has an address range of up to 64 bytes
of inputs and 64 bytes of outputs.