2. Commissioning

2.3.5 Parameterisation via the PLC user program (method 3)

Object
Instances
classes
(dec.)
4
100 ... 102
d
102
1 ... 48
d
103
1 ... 48
d
104
1 ... 48
d
105
1 ... 48
d
106
1 ... 48
d
107
1 ... 48
d
132
1
d
133
1
d
134
1 ... 40
d
135
1
d
Tab. 2/15: Overview of Object classes for EtherNet/IP (operating mode Remote I/O)
Festo P.BE-CPX-FB32-EN en 1111a
Program-controlled access to parameters is made via the
"Explicit Message" programming. The addresses of the
EtherNet/IP Object Model required for this can be found in
Appendix B. Information on programming this data
transmission can be found in the manual for your controller.
In order to address the CPX terminal with FB32 you will
require the following Object descriptions:
Detailed Object descriptions can be found in Appendix B.1.
Attri-
Name
butes
(dec.)
-
Assembly Object
1, 2
Modification digital inputs, Object
1 ... 6
Modification digital outputs, Object
1, 2
Modification analogue inputs, Object
1 ... 6
Modification analogue outputs, Object
1, 2
Modification input words of technology module, Object
1 ... 6
Modification output words of technology module, Object
1 ... 37
System Object (Global System Object)
1 ... 3
Status and Diagnostic Object
1 ... 12
Diagnostic Trace Object
1 ... 13
Diagnostic Trace Status Object
2-37