Festo CPX-FB32 Manual page 121

Cpx terminal, cpx field bus node, fieldbus protocol ethernet/ip
Hide thumbs Also See for CPX-FB32:
Table of Contents

Advertisement

B. Ethernet/IP Objects of the CPX-FB32
Attr.
Access
Name
No.
9
Get/Set
Error number filter
FN = error number
0: Error number filter inactive (presetting)
1: Record only defined FN
2: Do not record defined FN
3: reserved
10
Get/Set
Module/channel filter
With this diagnostic memory filter, the registering of
errors of other modules or channels can be
suppressed in order that errors in a particular
module or channel can be analysed.
FN = error number
0: Module/channel filter inactive (presetting)
1: Record only FN of a module
2: Record only FN of a channel
3: reserved
11
Get/Set
Module number
Module number for the diagnostic memory filter
12
Get/Set
Channel number
Channel number for the diagnostic memory filter
13
Get/Set
Error number
Fault number for the diagnostic memory filter
Festo P.BE-CPX-FB32-EN en 1111a
Type
Function
no.
BYTE
3484
(bits 4, 5)
BYTE
3484
(bits 6, 7)
BYTE
3485
(bits 0 ... 7)
BYTE
3486
(bits 0 ... 7)
BYTE
3487
(bits 0 ... 7)
B-23