Function
2.1.5

Priority Start-Up (Fast Start-Up)

The "Priority start-up" function ensures that the system CPX-E is able to start up quickly.
When using the "Priority start-up" function, crossover detection (auto MDI/MDI-X) must be deactiv-
ated and the bus module must be parameterised as a slave.
2.1.6
Identification & Maintenance (I&M)
The "Identification and Maintenance" (I&M) function serves as an electronic rating plate of the bus
module and offers uniform, manufacturer-independent access to device-specific online information
over the network.
2.1.7

Product Design

Fig. 2
2.1.8

Display Components

Fig. 3 LED displays
8
1 LED displays
2 Terminal strip for operating voltage supply U
[XD]
3 Terminal strip interlock
4 Network connection [XF2]
5 Linking element
6 Network connection [XF1]
1 Network-specific LED displays:
– Network fault [NF] (red)
– Maintenance [M/P] (yellow/green)
– Connection/data traffic [XF1]/[XF2] (green)
2 System-specific LED displays:
– Operating voltage supply U
– Load voltage supply U
– System error [SF] (red)
– Force mode [M] (yellow)
EL/SEN
[PS] (green)
EL/SEN
[PL] (green)
OUT
Festo — CPX-E-PN — 2020-01a