Technical data

Status of input
LED (green)
Meaning
Input active (logic 1)
Logic 1 at input
Illuminated
Input inactive (logic 0)
Logic 0 at input
Off
Tab. 10: LED status of input
10
Technical data
General technical data
Dimensions
(length × width × height)
Product weight
Ambient temperature
Storage temperature
Humidity (non-condensing)
Assigned address space
(inputs)
Module code (hex/dec)
Module identification
Protection against electric shock (protec-
tion against direct and indirect contact
in accordance with IEC 60204-1 and
IEC 60364-4-41)
Electromagnetic compatibility
Mounting position
Tab. 11: General technical data
12
[mm]
50.1 × 107.3 × 57.5 (including interlinking module)
[g]
86
[°C]
–20 ... +50
[°C]
–20 ... +70
[%]
5 ... 95
[Byte]
1
0x3009/12297d
CPX-AP-A-8DI-M12-5P
By the use of SELV/PELV circuits
(Safe extra-low voltage/Protected extra-low voltage)
See declaration of conformity è www.festo.com
Any
Remedy
Festo — CPX-AP-A-8DI-M12-5P — 2022-07