Technical data

Error
Description
code
E41
Specified value falls below the minimum
value
E42
The specified value exceeds the maximum
value
E43
Incorrect transfer value
E44
Data type incorrect
E93
General syntax error
E94
Syntax error index (variable x)
E95
Syntax error subindex (variable y)
E96
Syntax error value
E97
Command execution aborted
Tab. 36: Error codes communication
10

Disposal

ENVIRONMENT
Send the packaging and product for environmentally sound recycling in accordance with the current
regulations è www.festo.com/sp.
11
Technical data
VAEM-V-S8EPRS2
General
approval
ambient temperature
storage temperature
degree of protection
Pollution degree
product weight
dimensions W x L x H
Relative air humidity
Nominal altitude of use m ASL
vibration resistance
Festo — VAEM-V-S8EPRS2 — 2021-10a
RCM Mark
[°C]
0 ... 50
[°C]
–20 ... +70
IP20
2
[g]
98
[mm]
92 x 100 x 28
[%]
0 ... 95 Non-condensing
≤ 2000
Shock test with severity level 2 in accordance with EN 60068-2-6
(FN 942017-4)
Fault clearance
Check and correct value
Check and correct value
Check and correct the transfer value
Use correct data type
Check and correct the ASCII structure of the
input
Check and correct index and value
Check and correct subindex and value
Check and correct value
Repeat command or restart