Commissioning
5. Fit cover.
6. Tighten the retaining screws of the cover. Tightening torque: 0.4 Nm ± 10 %.
6.3.3

Network interface

The connection from the bus node to the network is effected with a specific connection technology.
Bus node
Connection technology
CPX-M-FB34
2x RJ45 bushing, push-pull, AIDA-compli-
ant, corresponding to IEC 60603, IEC
61076-3
Tab. 8 Connection technology and network connectors
Seal unused connections with cover caps or blanking plugs to achieve the specified degree of protec-
tion.
Network interface on bus node CPX-M-FB34
There are two RJ45 push-pull socket bushings (AIDA-compliant) on the bus node CPX-M-FB34 for the
network connection.
RJ45 bushing
Pin
Push-pull
1
2
3
4
5
6
7
8
Housing
Tab. 9 Pin allocation of network interfaces on bus node CPX-M-FB34 (RJ45)
Connect the bus node to the network with a Festo plug connector (FBD-RJ45-PP-GS).
The plug connector is designed for Ethernet lines with cable diameters 5 ... 8 mm.
18
Signal
Explanation
TD+
transmit data (transmit data, TD) +
TD
transmit data
RD+
receive data (receive data, RD) +
n.c.
Not connected
n.c.
Not connected
RD
receive data
n.c.
Not connected
n.c.
Not connected
Shield/FE
Shield/functional earth
Network connectors
Plug connector FBD-RJ45-PP-GS
Festo — MSE6-C2M — 2019-03