6 Function Parameters

6.1 What this chapter contains

This chapter lists and describes the function parameters.

6.2 CV50 general series function parameters

The function parameters of CV50 inverters have been divided into 30 groups (P00~P29) according to the
function, of which P18~P28 are reserved. Each function group contains certain function codes applying 3-level
menus. For example, "P08.08" means the eighth function code in the P8 group function, P29 group is factory
reserved, and users are forbidden to access these parameters.
For the convenience of function codes setting, the function group number corresponds to the first level menu,
the function code corresponds to the second level menu and the function code value corresponds to the third
level menu. CV50 includes the following function groups:
P00: Basic Function Group
P01: Start-up and stop control
P02: Motor data
P03: Vector Control
P04: SVPWM Control
P05: Input Terminals
P06: Output Terminals
P07: Human-mafchine interface
P08: Enhanced Function
P09: PID Control
P10: Simple PLC and Multi-step speed control
P11: Protective parameters
P13: Control parameters of Short circuit braking
P14: Serial communication
P17: Monitoring function
P24: Water Supply
1. Below is the instruction of the function lists:
The first column "Function code": codes of function parameter group and parameters;
The second column "Name": full name of function parameters;
The third column "Detailed instruction of parameters": detailed instruction of the function parameters;
The fourth column "Default value": the original factory set value of the function parameter.
The fifth column "Modify": the modifying character of function codes (the parameters can be modified or not
and the modifying conditions), below is the instruction:
"○": means the set value of the parameter can be modified on stop and running state
"◎": means the set value of the parameter can not be modified on the running state
"●": means the value of the parameter is the real detection value which can not be modified.
(The inverter has limited the automatic inspection of the modifying character of the parameters to help users
avoid mismodifying).
2. "Parameter radix" is decimal (DEC), if the parameter is expressed by hex, then the parameter is separated
from each other when editing. The setting range of certain bits are 0~F (hex).
3."The default value" means the function parameter will restore to the default value during default parameters
restoring. But the detected parameter or recorded value won't be restored.
4. For a better parameter protection, the inverter provides password protection to the parameters. After setting
32 - 144