Function
Name
code
Terminal
running
P01.18
protection
selection when
powering on
The running
frequency is
lower than the
lower limit one
P01.19
(valid if the
lower limit
frequency is
above 0)
Hibernation
P01.20
restore delay
time
Restart after
P01.21
power off
Function Parameters
Detailed instruction of parameters
When the running command channel is the terminal control,
the system will detect the state of the running terminal
during powering on.
0: The terminal running command is invalid when
powering on. Even the running command is detected to be
valid during powering on, the inverter won't run and the
system keeps in the protection state until the running
command is canceled and enabled again.
1: The terminal running command is valid when
powering on. If the running command is detected to be
valid during powering on, the system will start the inverter
automatically after the initialization.
Note: this function should be selected with cautions, or
serious result may follow.
This function code determines the running state of the
inverter when the set frequency is lower than the lower-limit
one.
0: Run at the lower limit frequency
1: Stop
2: Hibernation
The inverter will coast to stop when the set frequency is
lower than the lower-limit one. If the set frequency is above
the lower limit one again and it lasts for the time set by
P01.20, the inverter will come back to the running state
automatically.
This function code determines the hibernation delay time.
When the running frequency of the inverter is lower than the
lower limit one, the inverter will pause to stand by.
When the set frequency is above the lower limit one again
and it lasts for the time set by P01.20, the inverter will run
automatically.
Note: The time is the total value when the set frequency is
above the lower limit one.
Setting range: 0.0~3600.0s
(valid when P01.19=2)
This function can enable the inverter start or not after the
power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the inverter will run
automatically after waiting for the time defined by P01.22.
Default
Modify
value
0
0
0.0 s