Salicru CV50-008-4F User Manual page 40

Cv50 series
Table of Contents

Advertisement

Function
Name
code
Dead time of
P01.13
FWD/REV
rotation
Shifting
between
P01.14
FWD/REV
rotation
P01.15 Stopping speed 0.00~100.00Hz
Detection
P01.16
of stopping
speed
Detection time
P01.17
of the feedback
speed
40 - 144
Detailed instruction of parameters
Setting range of P01.09: 0.00Hz~P00.03 (the Max. frequency)
Setting range of P01.10: 0.00~50.00 s
Setting range of P01.11: 0.0~100.0 %
Setting range of P01.12: 0.00~50.00 s
During the procedure of switching FWD/REV rotation, set
the threshold by P01.14, which is as the table below:
Setting range: 0.0~3600.0 s
Set the threshold point of the inverter:
0: Switch after 0 frequency
1: Switch after the starting frequency
2: Switch after the speed reach P01.15 and delay for P01.24
0: Detect according to speed setting (no stopping delay)
1: Detect according to speed feedback (only valid for
vector control)
If set P01.16 to 1, the feedback frequency is less than or equal
to P01.15 and detect in the set time of P01.17, the inverter will
stop; otherwise the inverter will stop after the set time of P01.17
Setting range: 0.00~100.00 s (only valid when P01.16=1)
Default
Modify
value
0.0 s
0
0.50 Hz
1
0.50 s
Function Parameters