Salicru CV50-008-4F User Manual page 61

Cv50 series
Table of Contents

Advertisement

Function
Name
code
The parameter
P07.07
selection of the
stop state
Frequency
P07.08
display
coefficient
Rotation speed
P07.09
display
coefficient
Linear speed
P07.10
display
coefficient
Rectifier bridge
P07.11
module
temperature
Inverter module
P07.12
temperature
P07.13 Software version 1.00~655.35
Local
P07.14
accumulative
running time
High bit of power
P07.15
consumption
Low bit of power
P07.16
consumption
P07.17
Load type
Rated power of
P07.18
the inverter
Function Parameters
Detailed instruction of parameters
0x0000~0xFFFF
BIT0: set frequency
(Hz on, frequency flickering slowly)
BIT1: bus voltage (V on)
BIT2: input terminals state
BIT3: output terminals state
BIT4: PID reference (% flickering)
BIT5: PID feedback value (% flickering)
BIT6: reserved
BIT7: analog AI1 value (V on). Inverters≤15kW can be set
by the digital potentiometer on the keypad and AI1 setting is
not available for the devices ≥ 18.5kW.
BIT8: analog AI2 value (V on)
BIT9: analog AI3 value (V on)
BIT10: high speed pulse HDI frequency
BIT11: PLC and the current stage in multi-step speed
BIT12: pulse counters
BIT13: length value
BIT14: upper limit frequency (Hz on)
0.01~10.00
Displayed frequency=running frequency* P07.08
0.1~999.9%
Mechanical rotation speed =120*displayed running
frequency×P07.09/motor pole pairs
0.1~999.9%
Linear speed= Mechanical rotation speed×P07.10
0~100.0ºC
0~100.0ºC
0~65535h
Display the power used by the inverter.
The power consumption of the inverter =P07.15*1000+P07.16
Setting range of P07.15: 0~65535 kWh (*1000)
Setting range of P07.16: 0.0~999.9 kWh
0: Constant Torque Load
1: Variable Torque Load
0.4~3000.0kW
Default
Modify
value
0x00FF
1.00
100.0 %
1.0 %
61 - 144