Function
Name
code
B frequency
command
P00.08
reference
selection
Combination of
P00.09
the setting
source
Function Parameters
Detailed instruction of parameters
and -100.0% corresponds to the maximum frequency in
reverse direction (P00.03).
Note: The pulse setting can only be input by multi-function
terminal HDI. Set P05.00 (HDI input selection) to high
speed pulse input, and set P05.49 (HDI high speed pulse
input function selection) to frequency setting input.
5: Simple PLC program setting
The inverter runs at simple PLC program mode when P00.06=5
or P00.07=5. Set P10 (simple PLC and multi-step speed control)
to select the running frequency, running direction, ACC/DEC time
and the keeping time of corresponding step. See the function
description of P10 for detailed information.
6: Multi-step speed running setting
The inverter runs at multi-step speed mode when P00.06=6 or
P00.07=6. Set P05 to select the current running step, and set
P10 to select the current running frequency.
The multi-step speed has the priority when P00.06 or P00.07
does not equal to 6, but the setting step can only be the 1~15
step. The setting step is 0~15 if P00.06 or P00.07 equals to 6.
7: PID control setting
The running mode of the inverter is process PID control
when P00.06=7 or P00.07=7. It is necessary to set P09.
The running frequency of the inverter is the value after PID
effect. See P09 for the detailed information of the preset
source, preset value, and feedback source of PID.
8: MODBUS communication setting
The frequency is set by MODBUS communication. See P14
for detailed information.
9~11: Reserved
0: Maximum output frequency: 100% of B frequency
setting corresponds to the maximum output frequency
1: A frequency command: 100% of B frequency setting
corresponds to A frequency setting. Select this setting if it
needs to adjust on the base of A frequency command.
0: A, the current frequency setting is A frequency command
1: B, the current frequency setting is B frequency command
2: A+B, the current frequency setting is A frequency
command + B frequency command
3: A-B, the current frequency setting is A frequency
command - B frequency command
4: Max (A, B): the bigger one between A frequency
command and B frequency is the set frequency.
5: Min (A, B): The lower one between A frequency
command and B frequency is the set frequency.
Note:The combination manner can be shifted by P05
(terminal function)
Default
Modify
value
0
0
35 - 144