Salicru CV50-008-4F User Manual page 55

Cv50 series
Table of Contents

Advertisement

Function
Name
code
Upper limit of
P05.34
AI1
Correspon ding
P05.35
setting of the
upper limit of AI1
AI1 input filter
P05.36
time
Lower limit of
P05.37
AI2
Correspon ding
P05.38
setting of the
lower limit of AI2
Upper limit of
P05.39
AI2
Correspon ding
P05.40
setting of the
upper limit of AI2
AI2 input filter
P05.41
time
Lower limit of
P05.42
AI3
Correspon ding
P05.43
setting of the
lower limit of AI3
Middle value of
P05.44
AI3
Correspon ding
P05.45
middle setting of
AI3
Upper limit of
P05.46
AI3
Correspon ding
P05.47
setting of the
upper limit of AI3
AI3 input filter
P05.48
time
HDI high-speed
P05.49
pulse input
Function Parameters
Detailed instruction of parameters
input value, the inverter will count at the minimum or
maximum one.
When the analog input is the current input, the
corresponding voltage of 0~20mA is 0~10V.
In different cases, the corresponding rated value of 100.0%
is different. See the application for detailed information.
The figure below illustrates different applications:
Input filter time: this parameter is used to adjust the
sensitivity of the analog input. Increasing the value properly
can enhance the anti-interference of the analog, but
weaken the sensitivity of the analog input
Note: Analog AI1 and AI2 can support 0~10V or 0~20mA input,
when AI1 and AI2 selects 0~20mA input, the corresponding
voltage of 20mA is 5V. AI3 can support an input of -10V~+10V.
The setting range of P05.32: 0.00V~P05.34
The setting range of P05.33: -100.0%~100.0%
The setting range of P05.34: P05.32~10.00V
The setting range of P05.35: -100.0%~100.0%
The setting range of P05.36: 0.000s~10.000s
The setting range of P05.37: 0.00V~P05.39
The setting range of P05.38: -100.0%~100.0%
The setting range of P05.39: P05.37~10.00V
The setting range of P05.40: -100.0%~100.0%
The setting range of P05.41: 0.000s~10.000s
The setting range of P05.42: -10.00V~P05.44
The setting range of P05.43: -100.0%~100.0%
The setting range of P05.44: P05.42~P05.46
The setting range of P05.45: -100.0%~100.0%
The setting range of P05.46: P05.44~10.00V
The setting range of P05.47: -100.0%~100.0%
The setting range of P05.48: 0.000s~10.000s
The function selection when HDI terminals is high-speed
pulse input
0: Frequency setting input, frequency setting source
1: Counter input, high-speed pulse counter input terminals
2: Length counting input, length counter input terminals
Default
Modify
value
10.00 V
100.0 %
0.100 s
0.00 V
0.0 %
10.00 V
100.0 %
0.100 s
-10.00 V
-100.0 %
0.00 V
0.0 %
10.00 V
100.0 %
0.100 s
0
55 - 144