3.4 Name plate

3.5 Type designation key

The type designation contains information on the inverter. The user can find the type designation on the type
designation label attached to the inverter or the simple name plate.
Key
Product
Rated power
Voltage degree
EMC Filter
Product Overview
Mountable method
Temperature of the
running environment
Ingress protection
Cooling
Braking unit
EMC filter
Fig 3-3 Name plate
CV50 – 150 – 4F
Fig 3-4 Product type
No.
Detailed description
Model of the inverter
Power range
Voltage degree
Embedded EMC Filter
Wall, flange and floor mountable
-10~50ºC, derate 3% for each degree above 40ºC
IP20
Air-cooling
Built-in braking unit for inverters below 30kW (including
30kW)
External braking unit for others
Built-in C3 filter: meet the degree requirement of
IEC61800-3 C3
③④
CV50 Inverter
150: 15 kW constant torque load / 18.5 kW
variable torque load
550: 55 kW ctt torque / 75 kW var torque
3500: 350 kW ctt torque / 400 kW var torque
4: AC 3PH 380V(-15%)~440V(+10%)
"F" indicates that the inverter has an
embedded EMC Filter Category C3
Specification