Parameter
6.16.5

Password function (Pr. 296, Pr. 297)

Registering 4-digit password can restrict parameter reading/writing.
Pr.
Name
No.
296
Password lock level
Password lock/
297
unlock
The above parameters can be set when Pr. 160 = 0.
The above parameters allow its setting to be changed during operation in any operation mode
even if "0" is set in Pr. 77.
When Pr. 296 ≠ "9999" (with password lock), note that Pr. 297 is always available for setting
regardless of Pr. 160 setting.
Parameter reading/writing restriction level (Pr. 296)
Level of reading/writing restriction by PU/NET mode operation command can be selected by
Pr. 296.
Pr. 296
Tab. 6-34: Level of password lock and reading/writing restriction
If the parameter reading is restricted by the Pr. 160 setting, those parameters are unavailable
for reading even when "✔" is indicated.
If the parameter writing is restricted by the Pr. 77 setting, those parameters are unavailable
for writing even when "✔" is indicated.
Parameter access from unit where parameter is written in PU operation mode (initially set
to operation panel, parameter unit) is restricted. (For PU mode operation command source
selection refer to section 6.17.3.)
Parameter access in NET operation mode with RS485 communication is restricted.
FR-D700 SC EC
Initial
Setting Range
Description
Setting
Select restriction level of parameter
1–6/101–106
reading/ writing when a password is
9999
registered.
9999
No password lock
1000–9998
Register a 4-digit password
Displays password unlock error count.
(0–5)
(Reading only)
9999
(Valid when Pr. 296 = "101" to "106")
(9999)
No password lock (Reading only)
PU Mode Operation Command
Read
9999
1/101
2/102
3/103
4/104
5/105
6/106
Misoperation prevention and parameter setting restriction
Write
Parameters referred to
77
Parameter write
selection
160
Extended function
display selection
551
PU mode operation
command source
selection
NET Mode Operation Command
Read
Write
Refer to
Section
6.16.2
6.16.4
6.17.3
6 - 169