Mitsubishi Electric FR-D720S SC EC Instruction Manual page 369

Fr-d700 series
Table of Contents

Advertisement

Parameter
● Special monitor selection numbers.
Refer to section 6.10.2 for details of the monitor description.
Data
H01
H02
H03
H05
H07
H08
H09
H0A
H0B
H0C
H0E
H0F
Tab. 6-60: Special monitor selection numbers
When "0.01 to 9998" is set in Pr. 37 and "01" in instruction code HFF, the data format is 6
digits (E2).
Input terminal monitor details
(when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
Output terminal monitor details
(when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
FR-D700 SC EC
Description
Output frequency/speed
Output current
Output voltage
Frequency setting/speed setting
Motor torque
Converter output voltage
Regenerative brake duty
Electronic thermal relay function
load factor
Output current peak value
Converter output voltage peak value
Output power
Input terminal status
Unit
Data
Description
0.01Hz
H10
Output terminal status
0.001
0.01A
H14
Cumulative energization time
0.1V
H17
Actual operation time
0.01Hz
H18
Motor load factor
0.001
0.1%
H19
Cumulative power
0.1V
H34
PID set point
0.1%
H35
PID measured value
0.1%
H36
PID deviation
0.01A
H3D
Motor thermal load factor
0.1V
H3E
Inverter thermal load factor
0.01kW
H3F
Cumulative power 2
H40
PTC thermistor resistance
RH
SO
Communication operation and settings
RM
RL
ABC
Unit
1h
1h
0.1%
1kWh
0.1%
0.1%
0.1%
0.1%
0.1%
0.1kWh
0.01kΩ
b0
STR
STF
b0
RUN
6 - 219