Mitsubishi Electric FR-D720S SC EC Instruction Manual page 156

Fr-d700 series
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
DU/PU main display
52
data selection
AM terminal function
158
selection
Watt-hour meter clear
170
Operation hour meter
171
clear
Monitor decimal digits
268
selection
Energizing time
563
carrying-over times
Operating time
564
carrying-over times
Cumulative power
monitor digit shifted
891
times
Tab. 6-1:
Parameter overview (6)
6 - 6
Incre-
Initial
Setting
ments
value
range
0/5/8–12/
14/20/
1
0
23–25/
52–55/61/
62/64/100
1–3/5/8–12/
1
1
14/21/24/
52/53/61/62
0
10
1
9999
9999
1
9999
0/9999
0
1
9999
1
9999
1
0
0–65535
1
0
0–65535
0–4
1
9999
9999
Description
Selects monitor to be displayed on
the operation panel and parameter
unit and monitor to be output to
the terminal AM.
0:
Output frequency (Pr. 52)
1:
Output frequency (Pr. 158)
2:
Output current (Pr. 158)
3:
Output voltage (Pr. 158)
5:
Frequency setting value
8:
Converter output voltage
9:
Regenerative brake duty
10: Electronic thermal relay
function load factor
11: Output current peak value
12: Converter output voltage
peak value
14: Output power
20: Cumulative energization
time (Pr. 52)
21: Reference voltage output
(Pr. 158)
23: Actual operation time (Pr. 52)
24: Motor load factor
25: Cumulative power (Pr. 52)
52: PID set point
53: PID measured value
54: PID deviation (Pr. 52)
55: I/O terminal status (Pr. 52)
61: Motor thermal load factor
62: Inverter thermal load factor
64: PTC thermistor resistance
100:Set frequency is displayed
during a stop and output
frequency is displayed during
operation (Pr. 52).
Set "0" to clear the watt-hour meter
monitor.
Set the maximum value when
monitoring from communication
to 0 to 9999kWh.
Set the maximum value when
monitoring from communication
to 0 to 65535kWh.
Set "0" in the parameter to clear
the watt hour monitor.
Setting "9999" has no effect.
Displays the monitor as integral
value.
Displays the monitor in incre-
ments of 0.1.
No fixed decimal position
The numbers of cumulative ener-
gizing time monitor exceeded
65535h is displayed.
Reading only
The numbers of operation time
monitor exceeded 65535h is dis-
played.
Reading only
Set the number of times to shift
the cumulative power monitor
digit. Clamp the monitoring value
at maximum.
No shift
Clear the monitor value when it
exceeds the maximum value.
Parameter
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-111