Setting for the parameter unit and operation panel

6.21
Setting for the parameter unit and operation panel
Purpose
Selection of rotation direction by the
RUN key of the operation panel
Switch the display language of the
parameter unit
Use the setting dial of the operation
panel like a volume for frequency
setting.
Key lock of operation panel
Change the magnitude of change of
frequency setting by the setting dial
of the operation panel
Control of the parameter unit buzzer PU buzzer control
Adjust LCD contrast of the parame-
ter unit
6.21.1
RUN key rotation direction selection (Pr. 40)
Used to choose the direction of rotation by operating the RUN key of the operation panel.
Pr. No. Name
RUN key rotation
40
direction selection
The above parameter can be set when Pr. 160 = 0.
6.21.2
PU display language selection (Pr. 145)
By using parameter 145 you can select the display language for the parameter unit FR-PU04/
FR-PU07.
Pr. No. Name
PU display language
145
selection
The above parameter can be set when Pr. 160 = 0.
6 - 282
Parameters that must be set
RUN key rotation direction selection
PU display language selection
Operation panel operation selection
Magnitude of frequency change setting
PU contrast adjustment
Initial
Setting
Description
Value
Range
0
Forward rotation
0
1
Reverse rotation
Initial
Setting
Description
Value
Value
0
Japanese
1
English
2
German
3
French
1
4
Spanish
5
Italian
6
Swedish
7
Finnish
Parameter
Refer to
Section
Pr. 40
6.21.1
Pr. 145
6.21.2
Pr. 161
6.21.3
Pr. 295
6.21.4
Pr. 990
6.21.5
Pr. 991
6.21.6