Mitsubishi Electric FR-D720S SC EC Instruction Manual page 349

Fr-d700 series
Table of Contents

Advertisement

Parameter
6.18.3
Operation selection at communication error occurrence
(Pr. 121, Pr. 122, Pr. 502)
Pr.
Initial
Name
No.
Value
Number of PU
121
communica-
1
tion retries
PU communi-
122
cation check
9999
time interval
Stop mode
selection at
502
0
communica-
tion error
The above parameters can be set when Pr. 160 = 0.
FR-D700 SC EC
Setting
Description
Range
Number of retries at data receive error occurrence
If the number of consecutive errors exceeds the permissi-
ble value, the inverter will come to trip (depends on
0–10
Pr. 502).
Valid only Mitsubishi inverter (computer link operation)
protocol
If a communication error occurs, the inverter will not
9999
come to trip.
RS485 communication can be made. Note that a commu-
nication fault (E.PUE) occurs as soon as the inverter is
0
switched to the operation mode (network operation mode
in the initial setting) with the control.
Communication check (signal loss detection) time inter-
0.1
valIf a no-communication state persists for longer than
the permissible time, the inverter will come to trip
999.8 s
(depends on Pr. 502).
9999
No communication check (signal loss detection)
At fault occur-
Indication
rence
0
Coasts to stop E.PUE
Decelerates to
After stop
1
stop
E.PUE
Decelerates to
After stop
2
stop
E.PUE
Communication operation and settings
Parameters referred to
190/192/
At fault
Fault output
removal
Stop
Output
(E.PUE)
Output after
Stop
stop
(E.PUE)
Automatic
Without
restart
output
functions
Refer to
Section
7
Acceleration time
6.6.1
8
Deceleration time
6.6.1
Output terminal
6.9.5
197
function selection
6 - 199