Communication operation and settings
Example
When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station No. 0.
Tab. 6-58: Example for data transmission
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from
step
● List of calibration parameters
Pr.
C2
(902)
C3
(902)
125
(903)
C4
(903)
Tab. 6-59: Calibration parameters
6 - 218
Computer Send Data
ENQ 00 FF 0 01 82
ENQ 00 EC 0 01 7E
ENQ 00 5E 0 0F
STX 00 0000 ETX 25
ENQ 00 60 0 FB
STX 00 0000 ETX 25
again.
Name
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting
bias
Terminal 2 frequency setting
gain frequency
Terminal 2 frequency setting
gain
Inverter Send Data
Description
Set "H01" to the extended link parameter.
ACK 00
Set "H01" to second parameter changing.
ACK 00
C3 (Pr. 902) is read. 0% is read.
C6 (Pr. 904) is read. 0% is read.
Instruction
Code
Pr.
C5
5E
DE
1
(905)
C6
5E
DE
1
(904)
126
5F
DF
1
(905)
C7
5F
DF
1
(905)
Name
Terminal 4 frequency setting
bias frequency
Terminal 4 frequency setting
bias
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting
gain
Parameter
Instruction
Code
60
E0
1
60
E0
1
61
E1
1
61
E1
1