Parameter
Input terminal function assignment
Setting
Terminal Function
Pr. 59 = 0
(initial value)
0
RL
Pr. 59 ≠ 0
Pr. 59 = 0
(initial value)
1
RM
Pr. 59 ≠ 0
Pr. 59 = 0
(initial value)
2
RH
Pr. 59 ≠ 0
3
RT
Second function selection
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
7
OH
External thermal relay input
8
REX
15 speed selection (combination with three speeds RL, RM, RH)
Inverter operation enable signal
10
X10
(FR-HC-, FR-CV connection)
12
X12
PU operation external interlock
14
X14
PID control valid terminal
PU-external operation switchover
16
X16
(turning on X16 selects external operation)
18
X18
V/f switchover (V/f control is exercised when X18 is on)
24
MRS
Output stop
25
STOP
Start self-holding selection
37
X37
Traverse function selection
Forward rotation command
60
STF
(assigned to STF terminal (Pr. 178) only)
Reverse rotation command
61
STR
(assigned to STR terminal (Pr. 179) only)
62
RES
Inverter reset
PU/NET operation switchover
65
X65
(turning on X65 selects PU operation)
External/NET operation switchover
66
X66
(turning on X66 selects NET operation)
Command source switchover
67
X67
(turning on X67 makes Pr. 338 and Pr. 339 commands valid)
9999
No function
Tab. 6-11:
Input terminal function assignment
When Pr. 59 ≠ 0, the functions of the RL, RM and RH signals are changed as given in the
table.
The OH signal turns on when the relay contact "opens".
FR-D700 SC EC
Low-speed operation command
Remote setting (setting clear)
Middle-speed operation command
Remote setting (deceleration)
High-speed operation command
Remote setting (acceleration)
Function assignment of external terminals
Related Parameters
Pr. 4–Pr. 6, Pr. 24–Pr. 27,
Pr. 232–Pr. 239
Pr. 59
Pr. 4–Pr. 6, Pr. 24–Pr. 27,
Pr. 232–Pr. 239
Pr. 59
Pr. 4–Pr. 6, Pr. 24–Pr. 27,
Pr. 232–Pr. 239
Pr. 59
Pr. 44–Pr. 51
Pr. 267
Pr. 15, Pr. 16
Pr. 9
Pr. 4–Pr. 6, Pr. 24–Pr. 27,
Pr. 232–Pr. 239
Pr. 30, Pr. 70
Pr. 79
Pr. 127–Pr. 134
Pr. 79, Pr. 340
Pr. 80
Pr. 17
Pr. 592–Pr. 597
Pr. 79, Pr. 340
Pr. 79, Pr. 340
Pr. 338, Pr. 339
Refer to
Page
6-48
6-55
6-48
6-55
6-48
6-55
6-93
6-147
6-51
6-66
6-48
6-84
6-172
6-242
6-181
6-29, 6-74
6-91
6-94
6-264
6-94
6-94
6-184
6-184
6-186
6 - 89