Mitsubishi Electric FR-D720S SC EC Instruction Manual page 313

Fr-d700 series
Table of Contents

Advertisement

Parameter
Restarting method when stop was made by pressing the STOP key from the PU during
external operation ("PS" is displayed)
Operation panel
After the motor has decelerated to a stop, turn off the STF or STR signal.
Press the PU/EXT key to change to the PU operation mode. The PU indication is lit. The
message "PS" is canceled.
Press the PU/EXT key to change to the external operation mode. The EXT indication is lit.
Turn on the STF or STR signal.
Operation panel
Fig. 6-88: Stop during external operation
Parameter unit (FR-PU04/FR-PU07)
After completion of deceleration to a stop, switch off the STF or STR signal.
Press the EXT key. The message "PS" is canceled.
Switch on the STF or STR signal.
The motor can be restarted by making a reset using a power supply reset or RES signal.
NOTE
If Pr. 250 "Stop selection" is set to other than "9999" to select coasting to a stop, the motor
will not be coasted to a stop but decelerated to a stop by the PU stop function during exter-
nal operation.
FR-D700 SC EC
Speed
STF (ON)
STR (OFF)
Misoperation prevention and parameter setting restriction
PU key
STOP key
Time
I000027C
6 - 163

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-d740 sc ec

Table of Contents