Terminal connection diagram

3.2
Terminal connection diagram
Source Logic
Main circuit terminal
Control circuit terminal
Single-phase power input
MCCB
1-phase AC
power supply
MCCB
3-phase AC
power supply
Control input signals (No voltage input allowed)
Terminal functions vary
rotation start
with the input terminal
assignment set in
Pr. 178 to Pr. 182.
rotation start
High speed
Multi-speed
Middle speed
selection
Contact input common (sink*)
24V DC power supply/
max. 100mA load current
Contact input common (source*)
*(Common for external power supply transistor)
*2 When using terminals PC-SD as a 24V DC power supply,
take care not to short across terminals PC-SD.
Frequency setting signal (analog)
*3 Terminal input
specifications can be
changed by analog input
specifications switchover
potentiometer
(Pr. 73) (initial settings in
frame). Terminal 10 and
terminal 2 are used as PTC
input terminal (Pr. 561).
*4 It is recommended to use
1kΩ/2W when the
frequency setting signal is
changed frequently.
(Current input)
*5 Terminal input specifications can be changed by analog
input specifications switchover (Pr. 267) (initial settings in
frame).
Set the voltage/current input switch in the "V" position to
select voltage input (0 to 5 V/0 to 10 V) and "I" to select
current input (0/4 to 20 mA.)
To use terminal 4 (initial setting is current input), set "4" in
any of Pr.178 to Pr.182 to assign the function.
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
Fig. 3-3: Terminal connection diagram of the inverter
3 - 4
*1 DC reactor
When connecting a DC reactor, remove the
jumper across P1 and P/+.
MC
L1
N
Earth
MC
R/L1
S/L2
T/L3
Earth
STF
Forward
STR
Reverse
RH
RM
RL
Low speed
SD
PC
10(+5V)
3
*4
2
0–5V DC
Frequency
2
setting
0–10V DC
Ω,
1k
1/2W
5
Analog common
1
Terminal 4
(+)
4
4–20 mA DC
input
(-)
0–5V DC
0–10V DC
V
Voltage/current
input switch
Shorting wire
S1
S2
SC
Brake unit
(Option)
*1
*8
PR N/-
*6
Jumper
*7
P1
P/ +
*6
Inrush
current limit
circuit
Main circuit
Control circuit
C
B
A
24V
*2
PU
connector
*3
RUN
*5
SE
I
*5
SO
Output shutoff
circuit
24V
*6 FR-D720S-008SC to 100SC: +, –
FR-D740-012SC to 160SC: P/+, N/–
*7 A brake transistor is not built-in to the
FR-D720S-008SC and 014SC.
*8 Brake resistor (FR-ABR)
Install a thermal relay to prevent an overheat
and burnout of the brake resistor.
(The brake resistor can not be connected to
the FR-D720S-008SC and 014SC.).
V
W
Earth
Terminal functions vary with
the input terminal assignment
Relay output
set in Pr. 192.
(Alarm output)
(+)
AM
Analog signal output
(0–10V DC)
5
(-)
Open collector output
Terminal functions vary with the input
Running
terminal assignment set in Pr. 190.
Open collector output common
Sink/source common
Safety monitor output common
Terminal functions vary by Pr. 197
Safety monitor output
*9 Common terminal of terminal SO is terminal SE.
Wiring
M
Motor
3~
Relay output
*9
I002176E