Mitsubishi Electric FR-D720S SC EC Instruction Manual page 121

Fr-d700 series
Table of Contents

Advertisement

Basic settings
Selection method of General-purpose magnetic flux vector control
Motor
Mitsubishi
Other
manufac-
turer's
Perform offline auto tuning (Pr. 96, refer to section 5.1.8).
Set motor excitation current (Pr. 82, refer to section 6.7.3).
Set slip compensation (Pr. 245, Pr. 246, Pr. 247, refer to section 6.2.3).
Fig. 5-9: Selection method of general-purpose magnetic flux vector control
NOTES
Uneven rotation slightly increases as compared to the V/F control. It is not suitable for
machines such as grinding machine and wrapping machine which requires less uneven
rotation at low speed.
When a surge voltage suppression filter (FFR-DT or FFR-SI) is connected between the
inverter and motor, output torque may decrease.
FR-D700 SC EC
Perform secure wiring.
(Refer to section 3.2.)
Set the motor. (Pr. 71) (Refer to page 5-12.)
Standard motor,
high efficiency
motor
Constant-torque
motor
Standard motor
Constant-torque
motor
For other settings of Pr. 71, refer to section 6.7.2.
Refer to section 5.1.8 for offline auto tuning.
Set the motor capacity (Pr. 80) (refer to page 5-12).
Set the operation command (refer to section 5.2).
Test run
Pr. 71
SF-JR
SF-HR
Others
SF-JRCA 4P
SF-HRCA 4P
Others (SF-JRC, etc.)
Set motor capacity (kW) in Pr. 80 "Motor capacity".
(V/f control is performed when the setting is "9999" (initial value).
Select the start command and speed command.
1) Start command
– Operation panel: Setting by pressing the RUN key
– External command: Setting by forward rotation or reverse
rotation command (terminal STF or STR)
2) Speed command
– Operation panel: Setting by pressing the digital dial
– External analog command (terminal 2 or 4):
Give a speed command using the analog signal input to
terminal 2 (or terminal 4).
– Multi-speed command:
The external signals (RH, RM, RL) may also be used to give
speed command.
Simple mode parameter list
Remarks
0
Initial value
40
3
Offline auto tuning is necessary.
1
50
13
Offline auto tuning is necessary.
3
Offline auto tuning is necessary.
13
5 - 13

Hide quick links: