Selection and protection of a motor
Display during tuning
Monitor is displayed on the operation panel and parameter unit (FR-PU04/FR-PU07) during tun-
ing as below. The value displayed corresponds to the value of parameter 96.
Pr. 96
Setting
Tuning in progress
Normal end
Error end (when inverter protec-
tive function operation is acti-
vated)
Tab. 6-9: Display during tuning (monitor display)
NOTE
Die Selbsteinstellung dauert etwa 9 s.
The set frequency monitor displayed during the offline auto tuning is 0Hz.
6 - 78
Parameter Unit
(FR-PU04/FR-PU07) Display
11
READ:List
11
STOP
PU
TUNE
12
STF
FWD PU
TUNE
13
COMPETION
STF
STOP PU
TUNE
9
ERROR
STOP PU
STF
Parameter
Operation Panel Indication
11
Flickering