Mitsubishi Electric FR-D720S SC EC Instruction Manual page 152

Fr-d700 series
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
3
Base frequency
Base frequency voltage
19
Second V/f
47
(base frequency)
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
24
Multi-speed setting
4 speed to 7 speed
27
232
Multi-speed setting
8 speed to 15 speed
239
7
Acceleration time
8
Deceleration time
Acceleration/
deceleration reference
20
frequency
Second acceleration/
44
deceleration time
Second deceleration
45
time
Tab. 6-1:
Parameter overview (2)
6 - 2
Incre-
Initial
Setting
ments
value
range
0.01Hz
50Hz
0–400Hz
0–1000V
0.1V
8888
8888
9999
0–400Hz
0.01Hz
9999
9999
0.01Hz
50Hz
0–400Hz
0.01Hz
30Hz
0–400Hz
0.01Hz
10Hz
0–400Hz
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
0.1s
5/10s *
0–3600s
0.1s
5/10s *
0–3600s
0.01Hz
50Hz
1–400Hz
0.1s
5/10s *
0–3600s
0–3600s
0.1s
9999
9999
Description
Set the frequency when the motor
rated torque is generated. (50Hz/
60Hz)
Maximum inverter output voltage
95% of power supply voltage
Same as power supply voltage
Set the base frequency when the
RT signal is on.
Second V/f is invalid.
Set frequency when the RH signal
is on.
Set frequency when the RM signal
is on.
Set frequency when the RL signal
is on.
Frequency from 4 speed to 15
speed can be set according to the
combination of the RH, RM, RL
and REX signals.
9999: not selected
Set the motor acceleration time
* Initial values differ according to
the inverter capacity:
FR-D720S-008SC to 100SC
FR-D740-080SC or less/
FR-D740-120SC and 160SC
Set the motor deceleration time
* Initial values differ according to
the inverter capacity:
FR-D720S-008SC to 100SC
FR-D740-080SC or less/
FR-D740-120SC and 160SC
Set the frequency referenced as
acceleration/deceleration time. As
acceleration/deceleration time, set
the frequency change time from
stop to Pr. 20.
Set the acceleration/deceleration
time when the RT signal is on.
* Initial values differ according to
the inverter capacity:
FR-D720S-008SC to 100SC
FR-D740-080SC or less/
FR-D740-120SC and 160SC
Set the deceleration time when the
RT signal is on.
Acceleration time = deceleration
time
Parameter
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-44
6-48
6-59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-d740 sc ec

Table of Contents