Mitsubishi Electric FR-D720S SC EC Instruction Manual page 158

Fr-d700 series
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
Remote function
59
selection
Energy saving
60
control selection
65
Retry selection
Number of retries at
67
alarm occurrence
Retry waiting time
68
Retry count display
69
erase
66
Refer to Pr. 22 and Pr. 23
67
Refer to Pr. 65
69
70
Refer to Pr. 30
Tab. 6-1:
Parameter overview (8)
6 - 8
Incre-
Initial
Setting
ments
value
range
0
1
1
0
2
3
0
1
0
9
1
0
0–5
0
1–10
1
0
101–110
0.1s
1s
0.1–600s
1
0
0
Description
RH, RM, RL
Frequency setting
signal func-
storage function
tion
Multi-speed
setting
Remote
Yes
setting
Remote
No
setting
No (Turning STF/
Remote
STR off clears
setting
remote setting
frequency.)
Normal operation mode
Optimum excitation control mode
(OEC)
An alarm for retry can be selected.
No retry function
Set the number of retries at alarm
occurrence. An alarm output is not
provided during retry operation.
Set the number of retries at alarm
occurrence. (The setting value
minus 100 is the number of
retries.) An alarm output is pro-
vided during retry operation.
Set the waiting time from when an
inverter alarm occurs until a retry
is made.
Clear the number of restarts
succeeded by retry.
Parameter
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-55
6-143
6-138