Inspection
● Reinstallation of the fan
After confirming the orientation of the fan, reinstall the fan so that the arrow on the left of
"AIR FLOW" faces up.
NOTE
Installing the fan in the opposite air flow direction can cause the inverter life to be shorter.
Reconnect the fan connectors. When wiring, use care to avoid the cables being caught by
the fan.
FR-D720S-070SC and 100SC,
Fig. 8-5: Connection of the fan
Reinstall the fan cover. Insert hooks into the holes
sound.
Fig. 8-6: Reinstall the fan cover
8 - 8
AIR FLOW
Fan side face
FR-D740-080SC or less
FR-D720S-070SC and 100SC,
FR-D740-080SC or less
Example for FR-D740-036SC
Maintenance and inspection
Fig. 8-4:
Orientation of the fan
FR-D740-120SC or more
. Insert hooks
FR-D740-120SC or more
Example for FR-D740-160SC
I001864E
I001865E, I001866E
until you hear a click
I002008E