6. How to set a Parameter value

This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
Drive Supermarket and must not be reproduced or altered without prior written permission.
6.1 Select "PU" operation mode.
With the motor stopped, press the "PU/EXT" key
repeatedly until the "PU" indicator is illuminated and
"0.00" is displayed.
Note: If the operation mode is not changed to PU the
Inverter will not allow parameter values to be
changed and return an Er. 4 message.
6.2 Change mode to "Parameter setting".
Press the "MODE" key repeatedly until the "PRM"
indicator is illuminated. The display will show "P. 0" as
shown opposite (or the parameter which was last
selected).
6.3 Select the required parameter.
Use the dial to scroll through the parameters until the
desired parameter is shown. In this example, we will
select parameter 1 (as shown in the illustration opposite).
Press the "Set" key to select the parameter.
6.4 Change the parameter value and set.
The display will show the current parameter value. Use
the dial to increase or decrease the value as required. In
this case we will reduce the value from 120.0 to 50.00.
Press the "SET" key to save the new value. The display
will flash between parameter and value.
Press the "SET" key again to confirm.
Press "SET" one more time to return to the parameter list.
The next parameter in the list is shown.
©