Assembling The Front Assembly - Bandai Namco Time Crisis 5 Operation Manual

Table of Contents

Advertisement

8A-2 Assembling the Front Assembly
The front assembly refers to an assembly in which monitor tower (L) and (R) assemblies, the coin
box assembly, and the signboard assembly are all connected together.
● Assembling the front assembly requires work to be carried out while standing at an elevated location.
Prepare an appropriate footstool and exercise care during working. Working in an unnatural body posture
may result in injury or machine damage.
1
2
● Adjust the level adjusters to make the monitor tower (L) assembly flush with the monitor
3
Flange socket bolt (M6 x 12)
WARNING
Put the monitor tower (L) and (R) assemblies close together side by side so that there is no
gap at the top or bottom.
Monitor tower (L) assembly
While holding the monitor tower (L) and (R) assemblies close together, adjust the level
adjusters so that there is no gap between the base and monitor portions. (See P-77 "8A-4
Level Adjuster Adjustment")
tower (R) assembly.
Attach tower joint A to the front side of the assemblies using four flange socket bolts (M6 x
12) to connect them together.
Tower joint A
- Must be performed by a technician -
Monitor tower (R) assembly