8.9.3

NOT

FB/FC
FC
NOT is used for the NOT operation taking the inverse of a variable or constant.
Parameters
Parameter
name
In
Operand
Operation
Out
result
In
Out
Note:
The symbol ● indicates that the parameter is allowed to connect to the variable or constant of the data type.
Function Explanation
NOT is used for the bitwise NOT operation taking the inverse of the value of a variable or constant
and the result is output to Out.
The operational rule:
If one bit of the input variable is TRUE, the corresponding bit of the output variable is FALSE. If one
bit of the input variable is FALSE, the corresponding bit of the output variable is TRUE.
_8
The data type of Out must be the same as In.
Precautions for Correct Use
The input variables are not allowed to omit. An error will occur during the compiling of the software if any
input variable is omitted. But the output variable is allowed to omit.
8-116
Input/
Meaning
Output
Input parameter to take the
Input
inverse
Output
Not operation result
Bit string
Bit7
In
0
0
1
1
Out
Explanation
NO T
EN
ENO
In
Ou t
Description
Depends on the data type of the
variable that the input parameter is
connected to.
Depends on the data type of the
variable that the output parameter is
connected to.
Integer
1
1
0
1
0
0
1
0
Applicable
model
DVP15MC11T
Valid range
Real
Time, date
number
B it0
0
0
1
1