Delta Electronics Programmable Logic Controller DVP-EH Series Instruction Sheet

Delta Electronics Programmable Logic Controller DVP-EH Series Instruction Sheet

Programmable logic controller

Advertisement

Quick Links

Warning
Always read this instruction sheet thoroughly before using DVP EH digital I/O extension unit.
This is an OPEN TYPE extension unit. The extension unit should be kept in an enclosure away from airborne, dust,
high humidity, electric shock risk and vibration. Also, it is equipped with protective methods such as special tools or
keys to open the enclosure, so as to avoid the hazard to users and damage the extension unit.
DO NOT connect AC main circuit power supply to any of the input/output terminals, as it will damage the extension
unit. Check all the wiring prior to power up. DO NOT touch terminals when power on.
Introduction
Thank you for choosing Delta DVP-EH series PLC. The main processing units offer 8 ~ 48 points and the
maximum input/output can be extended up to 256 points.
Product Profile and Outline
5
2
7
5
2
5
7
5
4
1
4
3
3
7
3
Dimension (mm)
Model
Length
Width
DVP08HM11N
90
40
DVP16HM11N
90
55
DVP08HN11R/T
90
40
DVP16HP11R/T
90
55
6
9
2
8
7
1
6
6
Dimension (mm)
Model
Length
Width
4
10
DVP32HN00R/T
90
143.5
11
3
DVP32HP00R/T
90
143.5
3
3
7
DVP48HP00R/T
90
174
1. Power, low voltage indicators
5. Extension wiring
9. Cover
2. I/O terminals
6. Extension port cover
10. Input indicators
3. DIN rail clip
7. Direct mounting holes
11. Output indicators
4. DIN rail
8. Model name
DVP EH Series Model
Input unit
Output unit
Model
Power
Points
Type
Points
Type
DVP08HM11N
8
0
N/A
DVP16HM11N
16
0
DVP08HN11R
0
8
DVP08HP11R
4
4
Relay: 250V AC/30V DC 2A/1point
DC Type
24V DC
Sink/Source
DVP16HP11R
8
8
DVP08HN11T
0
8
DVP08HP11T
4
4
Transistor: 5 ~ 30V DC 0.3A/1point at 40° C
DVP16HP11T
8
8
Input unit
Model
Power
Points
Type
Points
DVP32HN00R
0
32
DVP32HP00R
16
16
DVP48HP00R
24
DC Type
24
100 ~ 240V
AC
DVP32HN00T
0
Sink/Source
32
DVP32HP00T
16
16
DVP48HP00T
24
24
Specifications
Electrical Specification
Model
08HM11N
08HN11R/T 08HP11R/T 16HP11R/T 32HN00R/T
Item
16HM11N
Power supply voltage
24V DC (20.4 ~ 28.8V DC) (-15% ~ 20%)
Power consumption
1W/1.5W
1.5W
1.5W
2W
24V DC supply current
NA
NA
NA
NA
Power protection
24V DC output with short-circuit protection
Voltage withstand
1,500V AC (Primary-secondary), 1,500V AC (Primary-PE), 500V AC (Secondary-PE)
Insulation resistance
> 5 M at 500V DC (Between all input/output and earth)
ESD: 8KV Air Discharge, EFT: Power Line: 2KV, Digital I/O: 1KV, Analog &
Noise immunity
Communication I/O: 250V,
Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m
The diameter of grounding wire cannot be smaller than the wire diameter of the terminals Land
Grounding
N (All DVP units should be grounded directly to the ground pole.)
Operation: 0
C ~ 55° C (temperature), 50 ~ 95% (humidity), Pollution degree 2;
°
Environment
Storage: -25
C ~ 70
C (temperature), 5 ~ 95% (humidity)
°
°
Vibration/shock
Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
resistance
Weight (g)
124/160
130/120
136/116
225/210
Approvals
I/O Terminal Specification
Input point
Input point type
DC
Input type
DC (SINK or SOURCE)
Input current
24V DC 5mA
Off
O n, above 16.5V DC
Active level
On
O ff, below 8V DC
Reaction time
About 20ms
Circuit isolation
Photocoupler/LED On
/operation indicator
Output point
Output point type
Relay-R
Current specification
1.5A/1point (5A/COM)
Voltage specification
Below 250V AC, 30V DC
75VA (inductive)
Maximum load
90W (resistive)
Reaction time
About 10ms
Installation and Wiring
ENGLISH
Digital I/O Terminal Wiring
DVP-08HM (8in)
08HM
08HN
X0 X 2
X 4 X 6
Y0 Y1 Y3
S/S
X 1 X 3
X 5 X 7
DVP-08HP (4in/4out)
08HP
16HM
X 0
X 2
Y0
Y1 Y 3
S/S
X10 X 11
S /S X 1 X3
C0 Y2
S /S
DVP-16HP (8in/8out)
DVP-32HN(32out)
16HP
32HN
(AC Power IN)
S /S
X4 X5
X6 X7
Y4 Y5 Y 6
Y 7
X0
X 1
X 2
X3
C 0 Y 0
Y 1
Y2
Y3
Y16
1
C4
S/S
X0
X2
X4
X6
X1 0
X12
X14
X16
X1
X3
X5
X7
X11
X13
X15
X1 7
DVP-32HP(16in/16out)
DVP-48HP(24in/24out)
32HP
48HP
(AC Power IN,DC Signal IN)
(AC Power IN,DC Signal IN)
Y0
Y1
Y3
Y4 Y5
Y7
Y1 0
Y11
Y13
Y1 4
Y1 5
Y17
Y0
Y1
C0
Y2
C1
Y6
C2
Y1 2
C3
Y16
C0
7
Mounting Arrangements and Wiring Notes
3
DIN Rail Installation:
The DVP-PLC can be secured to a cabinet by using the DIN
Height
rail that is 35mm high with a depth of 7.5mm. When
mounting the PLC on the DIN rail, be sure to use the end
82
bracket to stop any side-to-side motion of the PLC, thus to
82
reduce the chance of the wires being pulled loose. On the
bottom of the PLC is a small retaining clip. To secure the
82
PLC to the DIN rail, place it onto the rail and gently push up
82
on the clip. To remove it, pull down on the retaining clip and
gently pull the PLC away from the DIN rail. Please see the
figure on the right:
Direct Mounting: Use the specified dimensions and install with M4 screws.
Height
1. Please use O-type or Y-type terminals for I/O wiring terminals. The
82.2
specification for the terminals is as shown on the left. PLC terminal screws
Wiring:
82.2
should be tightened to between 5 ~ 8 kg-cm (4.3 ~ 6.9 in-lbs). Use copper
conductor only, 60° C/75° C.
82.2
2. DO NOT wire to the No Function terminals
Below 6.2
supply should not run through the same multi-wire cable or conduit.
3. When tightening the screws and performing wiring, please avoid that
To suit M3.5 screw terminal
metallic particles fall into PLC. After completing wiring, please remove the
label which is used to obstruct the metallic particles on the ventilation hole
Below 6.2
for well heat dissipation.
4. There should be a 50mm or more distance between the PLC and other
control component. Also, keep the PLC away from high voltage line and
power equipment.
Environment:
DO NOT store the PLC in an airborne dust, smoky, metallic particles, corrosive or flammable gases.
1.
2. DO NOT store the PLC in a location where temperatures and humidity will exceed specification.
3. DO NOT mount the PLC in a location where vibration and shock will exceed specification.
I/O Point Serial Sequence
When connecting MPU with less than 32 points to extension unit, the input number of 1
started from X20 in sequence and the output number is started from Y20 in sequence. If connecting MPU with
more than 32 points to extension unit, the input number of the 1
st
number of the MPU in sequence and the output number is started form the last output number of the MPU in
sequence.
Output unit
Type
Input
PLC
Model
points
Relay: 250V AC/30V DC 2A/1point
MPU
16EH/32EH/64EH
8/16/32
EXT1
32HP
16
EXT2
48HP
24
Transistor: 5 ~ 30V DC 0.3A/1 point at 40° C
EXT3
08HP
4
EXT4
08HN
0
In system application example, if the input/output of the 1
as 16 and thus there are no corresponding input/output for higher numbers. The input/output number of
extension number is the sequential number from the last number of the MPU.
Power Input Wiring and Specification
32HP00R/T
48HP00R/T
The power input for DVP-EH series PLC is AC input. Please pay particular attention to the following notes:
1. Connect the AC input (100 ~ 240V) to terminals L and N. Any 110V AC or 220V AC connected to the +24V
100~240V AC (-15%~10%), 50/60Hz ± 5%
terminal or input points will permanently damage the PLC.
30VA
30VA
30VA
2. The AC power inputs for the MPU and the I/O Extension Unit should be ON or OFF at the same time.
NA
500mA
500mA
3. Please use wires of 1.6mm or above for the grounding of the MPU.
4. If the power-cut time is less than 10ms, the PLC still operates unaffectedly. If the power-cut time is too long or
the power voltage drops, the PLC will stop operation and all outputs will be off. Once power is on again, the
PLC will resume automatically. (There are latched auxiliary relays and registers inside of the PLC, please be
aware when programming.)
100~240VAC
AC Input
Type
The +24V supply output is rated at 0.5A as max. from MPU. DO NOT connect external power
supply to this termianl. Moreover, it takes 6 ~ 7mA to drive each input point, so total of 100mA
660/590
438/398
616/576
is needed for 16 input points. As a result, the output load of +24V should not exceed 400mA.
Since the PLC is in control of numerous devices, operation of either one device could affect the operation of
other devices; therefore, the breakdown of either one device would consequently be detrimental to the whole
auto control system, and danger will thus be resulted. Please use the recommended wiring below for the power
input:
5
4
8
Guard
Lim it
MC
3
L
N
24 VDC
OV
6
6
Transistor-T
55°C 0.1A/1point, 50°C 0.15A/1point,
45° C 0.2A/1point, 40°C 0.3A/1point (2A/COM)
30V DC
Input/Output Point Wiring
9W
Input Point Wiring
Off
O n 15us On
O ff 25us
There are SINK and SOURCE types for the input signal of the input point with DC input. Definition as follows:
Sink = Current flow into common terminal S/S
S/S
Sinking
X0
DVP-08HN (8out)
Y4 Y5 Y7
Input point loop equivalent circuit
DC Type
C0 Y2
C1 Y6
(DC Signal IN)
DVP-16HM (16in)
SINK Mode
X12 X13 X 14 X15 X16 X 17
X 0
X1
X2
X 3
X4 X5
X6
X7
(Current flows into the
common terminal S/S)
C0
Y1
C1
Y4
C2
Y7
Y11
C3
X14
Y2
Y3
Y5
Y6
Y10
Y12
X15
Input point loop equivalent circuit
DC Type
Y21 Y22 Y23
Y25
Y26
Y27
Y31
Y32
Y34
Y36
(DC Signal IN)
Y20
C5
Y24
C6
Y30
C7
Y33
Y35
Y37
X22
S/S
X0
X2
X4
X6
X10
X12
X14
X16
X20
X24
X26
X1
X3
X5
X7
X11
X13
X15
X17
X21
X23
X25
X27
SOURCE Mode
(Current flows out of
common terminal S/S)
Y3
Y4 Y5
Y7
Y10
Y11
Y13
Y14
Y15
Y17
Y20
Y22
Y24
Y26
Y2
C1
Y6
C2
Y12
C3
Y16
C4 Y21
Y23
Y25
Y27
Output Point Wiring
For heat dissipation. Make
sure to provide a minimum
Relay output wiring
clearance of 50mm between
the unit and all sides of the
cabinet. (shown as below)
C0
Y0
C1
Y1
C2
MC2
2
5
2
8
> 5 0 mm
9
3
7
D V P MP U
> 5 0mm
> 5 0 mm
5
> 5 0 mm
10
*1: There is no protection circuit for the Relay output in the PLC. If DC conductive loading is on, add a diode in reverse direction in
parallel to extend the life of the Relay. The diode in reverse direction should correspond to the following specification:
. I/O signal wires or power
- The diode is able to withstand 5~10+ times loading voltage as maximum.
- The forward current of the diode must be greater than loading current.
*2: Use external hardware interlock and those in the PLC program to secure any emergent errors with safety protection.
*3: There is no protection circuit for the Relay in the PLC. If AC conductive loading is on, connect a surge absorber (0.1uF+ "100ohm to
120ohm") to reduce interference and extend the life of the Relay.
Transistor output wiring
C0
Y0
C1
Y1
C2
MC2
6
5
7
8
3
2
3
st
extension unit is
extension unit is started from the last input
*1: Use external hardware interlock and those in the PLC program to secure any emergent errors with safety protection.
*2: Use Zener diode (39V) inside the PLC to protect the transistor. If conductive loading is on, adding a diode in reverse direction in
parallel is recommended.
MP U
EXT1 EXT2 EXT3 EXT4
Output
Input number
Output number
points
8/16/32
X0~X7/X0~X17/X0~X37
Y0~Y7/Y0~Y17/Y0~Y37
16
X20~X37/X20~X37/X40~X57
Y20~Y37/Y20~Y37/Y40~Y57
24
X40~X67/X40~X67/X60~X107
Y40~Y67/Y40~Y67/Y60~Y107
4
X70~X73/X70~X73/X110~X113
Y70~Y73/Y70~Y73/Y110~Y113
8
-
Y74~Y103/Y74~Y103/Y114~Y123
st
MPU are less than 16, its input/output will be defined
產 品 外 觀 及 各 部 介 紹
L
N
+24V 24G
S/S
X0
X1
X2
2.0 A
DC/DC
+5V
Power supply for AC loads
1.
Fuse for circuit protection (3A limit)
2.
Power on pilot indicator
3. DIN
1
Emergency stop: a manual stop button is provided for emergency
4. DIN
to disconnect system power.
2
機 種 型 號
Circuit isolation device (System Power Disconnect): use
electromagnetic contactor and the relay to be the isolation unit of
MC
the power circuit to prevent the possible instability of the system
1
when the power is supplied on and off.
DVP PLC MPU (main processing unit)
7
Class three grounding.
Power supply:
AC: 100 ~ 240V AC, 50/60Hz
DC: 24V DC
Source = Current flows out of common terminal S/S
X0
S/S
Sourcing
Wiring loop
SINK
+24V
24VDC
+5V
24G
S/S
+24V
24G
S/S X0
X1 X2
X0
Sink Type
電 氣 規 格
Wiring loop
SOURCE
+24V
24VDC
+5V
24G
S/S
+24V
24G
S/S X0
X1
X2
X0
Source Type
24V DC
24V DC
DO NOT wire to the No Function terminals
Fuse
Diode in reverse direction to protect the relay*1
Y2
Y3
Y4
Y5
Mutually exclusive outputs*2
1
MC1
Emergency stop: use an external switch
Surge absorber*3
MC1
MC2
7
6
Conductive loading
4
Incandescent lamp (resistive loading)
DC supply
AC supply
輸 入
DO NOT wire to the No Function terminals
Emergency stop
Fuse
Y2
Y4
Y5
Y3
Mutually exclusive output*1
1
MC1
DC apply
Incandescent lamp (resistive loading)
MC1
MC2
6
Diode in reverse direction to protect the transistor*2
4
9
Conductive loading
Resistive loading
注 意 事 項
(OPEN TYPE)
( :
)
/
產 品 簡 介
DVP-EH
EH 8 ~ 48
/
5
2
2
5
7
5
7
1
5
4
1
4
3
3
7
3
(mm)
DVP08HM11N
90
40
82
DVP16HM11N
90
55
82
DVP08HN11R/T
90
40
82
DVP16HP11R/T
90
55
82
6
7
9
2
8
6
6
1
(mm)
(w)
4
10
DVP32HN00R/T
90
143.5
11
DVP32HP00R/T
90
143.5
3
DVP48HP00R/T
90
174
3
3
7
5.
9.
/
10.
6.
7.
11.
8.
DVP08HM11N
8
0
DVP16HM11N
16
0
DVP08HN11R
0
8
DVP08HP11R
4
4
Relay 250V AC/30V DC 2A/1
DC Type
24V DC
Sink/Source
DVP16HP11R
8
8
DVP08HN11T
0
8
Transistor 5 ~ 30V DC 0.3A/1
DVP08HP11T
4
4
@40°C
DVP16HP11T
8
8
DVP32HN00R
0
32
DVP32HP00R
16
16
Relay 250V AC/30V DC 2A/1
DVP48HP00R
24
DC Type
24
100 ~ 240V
DVP32HN00T
AC
0
Sink/Source
32
Transistor 5 ~ 30V DC 0.3A/1
DVP32HP00T
16
16
@40 C
DVP48HP00T
24
24
規 格
08HM11N
08HN11R/T 08HP11R/T 16HP11R/T 32HN00R/T 32HP00R/T 48HP00R/T
16HM11N
100 ~ 240V AC (-15% ~ 10%),
24V DC (20.4V DC ~ 28.8V DC) (-15% ~ 20%)
50/60Hz ± 5%
1W / 1.5W
1.5W
1.5W
2W
30VA
30 VA
NA
NA
NA
NA
NA
500 mA
24V DC
1,500V AC (Primary-secondary), 1,500V AC (Primary-PE), 500V AC (Secondary-PE)
5 M
/
500V DC
ESD: 8KV Air Discharge, EFT: Power Line: 2KV, Digital I/O: 1KV, Analog &
Communication I/O: 250V,
Digital I/O: 1KV, RS: 26MHz ~ 1GHz, 10V/m
L, N
PLC
0 ~ 55°C
50 ~ 95%
2
/
-25 ~ 70°C
5 ~ 95%
/
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
(g)
124/160
130/120
136/116
225/210
660/590
438/398
/
出 點 規 格
SINK
SOURCE
24V DC 5mA
Off → On 16.5V DC
On → Off 8V DC
20ms
/
/LED On
-R
-T
55°C 0.1A/1
50°C 0.15A/1
1.5A/1
5A/COM
45°C 0.2A/1
40°C 0.3A/1
250V AC,30V DC
30V DC
75VA
9W
90 W
10 ms
Off → On 15us
On → Off 25us
繁 體 中 文
/
256
7
3
82.2
82.2
82.2
30 VA
500 mA
616/576
2A/COM

Advertisement

loading

Summary of Contents for Delta Electronics Programmable Logic Controller DVP-EH Series

  • Page 1 24V DC DO NOT wire to the No Function terminals • Fuse Diode in reverse direction to protect the relay*1 Mutually exclusive outputs*2 Emergency stop: use an external switch Surge absorber*3 Conductive loading Incandescent lamp (resistive loading) DC supply AC supply 輸...
  • Page 2 安 裝 及 配 線 數 位 擴 充 機 之 端 子 配 置 圖 DVP-08HM (8in) DVP-08HN (8out) 08HM 08HN X0 X Y0 Y1 Y3 Y4 Y5 Y7 S/ S C0 Y2 C1 Y6 DVP-08HP (4in/4out) DVP-16HM (16in) (DC Signal IN) 08HP 16HM...

This manual is also suitable for:

Dvp-eh dido